Pipes, Valves, Flanges, Fittings, Welding Equipment, Welding Automation, Sprinkler Systems, Deluge Systems, Fire Pump Sets, Hydrant, Hose Reels & Hose Racks, Portable Extingui
You are viewing an unstyled version of this page. Either your browser does not support Cascading Style Sheets (CSS) or CSS styling has been disabled.
FSP-851 FSP-851T FSP-851R

Zoom

Category: Addressable Detectors
Manufacturer: NOTIFIER
SKU: 03022
Quantity:


Notifier 851 Series intelligent plug-in smoke detectors with integral communication provide features that surpass conventional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector’s address to be set with decade address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. The FSP-851 photoelectric detector’s unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-temperature thermal sensing on the FSP-851T. The FSP-851R is a remote test capable detector for use with DNR(W) duct detector housings. FSP-851 series detectors are compatible with all ONYX series Notifier intelligent Fire Alarm Control Panels (FACP).

Specifications
Size: 2.1” (5.3cm) high x 4.1” (10.4cm) diameter 
installed in B501 base, 6.1” (15.5cm) diameter 
installed in B710LPbase.
Shipping Weight: 5.2oz. (147g). 
Operating Temperature: FSP-851, 0°C to 49°C
(32°F to 120°F); FSP-851T, 0°C to 38°C (32°F to 100°F).
Low temperature signal for FSP-851T at 45°F +/- 10°F
(7.22°C +/- 5.54°C). FSP-851R installed in a DNR(W),
-20°C to 70°C (-4°F to 158°F).
UL/ULC Listed Velocity Range: 0-4000 ft/min.
(1219.2 m/ min.), suitable for installation in ducts.
Relative Humidity: 10%-93% noncondensing.
Thermal Ratings: Fixed-temperature setpoint 135°F (57°C)..
  
Agency Listings and Approvals
UL Listed: S1115
ULC Listed: S1115 (FSP-851A, FSP-851TA)
MEA Listed: 225-02-E
• FM Approved
CSFM: 7272-0028:206
Maryland State Fire Marshal: Permit # 2122
BSMI: CI313066760036
CCCF: Certif. # 2004081801000017
(FSP-851T) Certif. # 2004081801000016 (FSP-851)
Lloyd’s Register: 03/60011



Models No. Description
FSP-851 Low-profile intelligent photoelectric sensor. Must be mounted to one of the bases listed below.
FSP-851A Same as FSP-851 but with ULC listing.
FSP-851T Same as FSP-851 but includes a built-in 135°F (57°C) fixed-temperature thermal device.
FSP-851TA Same as FSP-851T but with ULC listing.
FSP-851R Low-profile intelligent photoelectric sensor, remote test capable. For use with DNRW.
FSP-851RA Same as FSP-851R but with ULC listing.